Restriction on Use of Load Instruction for Flag-Register
Oct,2006
- Product name:
-
- TOSHIBA Microcontrollers T4X Series
Dear Customer
With regard to our T4X Series of 4-bit microcontrollers, we have found that the following problem may occur when some data is loaded from Work RAM to Flag-Register. If this issue presents you with any problem, please contact your local Toshiba sales office.
- Problem
- Memory Bank Information (DMB) for Work RAM may have an unexpected value when executing Load Instruction from Work RAM to Flag-Register.
- Condition
- Condition 1: execute “LD F,M” instruction
Condition 2: execute “LDB AF,M” instruction
If you execute writing operations to Memory Bank information (DMB 2, 3) at Flag-Register in any of the two above-mentioned conditions, a problem may occur. - Caution
- Do not use both instructions, “LD F,M” and “LDB AF,M”.
- Inquiries
- To Inquiries on our products.